Type B thermocouple table: mV vs °C (0 to 1820 °C)
Type B thermocouple voltage in mV from 0 to 1820 °C in 10 °C steps, from the NIST (ITS-90) reference functions with the reference junction at 0 °C.
A type B thermocouple (platinum with 30% rhodium (+) and platinum with 6% rhodium (−)) produces a voltage that depends on the temperature difference between the measuring junction and the reference junction. The table follows the NIST (ITS-90) reference functions, with the reference junction at 0 °C.
Below about 50 °C the type B voltage is almost zero (slightly negative between 0 and about 40 °C) and does not identify the temperature. Type B is meant for high temperatures.
| °C | mV |
|---|---|
| 0 | 0.000 |
| 10 | −0.002 |
| 20 | −0.003 |
| 30 | −0.002 |
| 40 | 0.000 |
| 50 | 0.002 |
| 60 | 0.006 |
| 70 | 0.011 |
| 80 | 0.017 |
| 90 | 0.025 |
| 100 | 0.033 |
| 110 | 0.043 |
| 120 | 0.053 |
| 130 | 0.065 |
| 140 | 0.078 |
| 150 | 0.092 |
| 160 | 0.107 |
| 170 | 0.123 |
| 180 | 0.141 |
| 190 | 0.159 |
| 200 | 0.178 |
| 210 | 0.199 |
| 220 | 0.220 |
| 230 | 0.243 |
| 240 | 0.267 |
| 250 | 0.291 |
| 260 | 0.317 |
| 270 | 0.344 |
| 280 | 0.372 |
| 290 | 0.401 |
| 300 | 0.431 |
| 310 | 0.462 |
| 320 | 0.494 |
| 330 | 0.527 |
| 340 | 0.561 |
| 350 | 0.596 |
| 360 | 0.632 |
| 370 | 0.669 |
| 380 | 0.707 |
| 390 | 0.746 |
| 400 | 0.787 |
| 410 | 0.828 |
| °C | mV |
|---|---|
| 420 | 0.870 |
| 430 | 0.913 |
| 440 | 0.957 |
| 450 | 1.002 |
| 460 | 1.048 |
| 470 | 1.095 |
| 480 | 1.143 |
| 490 | 1.192 |
| 500 | 1.242 |
| 510 | 1.293 |
| 520 | 1.344 |
| 530 | 1.397 |
| 540 | 1.451 |
| 550 | 1.505 |
| 560 | 1.561 |
| 570 | 1.617 |
| 580 | 1.675 |
| 590 | 1.733 |
| 600 | 1.792 |
| 610 | 1.852 |
| 620 | 1.913 |
| 630 | 1.975 |
| 640 | 2.037 |
| 650 | 2.101 |
| 660 | 2.165 |
| 670 | 2.230 |
| 680 | 2.296 |
| 690 | 2.363 |
| 700 | 2.431 |
| 710 | 2.499 |
| 720 | 2.569 |
| 730 | 2.639 |
| 740 | 2.710 |
| 750 | 2.782 |
| 760 | 2.854 |
| 770 | 2.928 |
| 780 | 3.002 |
| 790 | 3.078 |
| 800 | 3.154 |
| 810 | 3.230 |
| 820 | 3.308 |
| 830 | 3.386 |
| °C | mV |
|---|---|
| 840 | 3.466 |
| 850 | 3.546 |
| 860 | 3.626 |
| 870 | 3.708 |
| 880 | 3.790 |
| 890 | 3.873 |
| 900 | 3.957 |
| 910 | 4.041 |
| 920 | 4.127 |
| 930 | 4.213 |
| 940 | 4.299 |
| 950 | 4.387 |
| 960 | 4.475 |
| 970 | 4.564 |
| 980 | 4.653 |
| 990 | 4.743 |
| 1000 | 4.834 |
| 1010 | 4.926 |
| 1020 | 5.018 |
| 1030 | 5.111 |
| 1040 | 5.205 |
| 1050 | 5.299 |
| 1060 | 5.394 |
| 1070 | 5.489 |
| 1080 | 5.585 |
| 1090 | 5.682 |
| 1100 | 5.780 |
| 1110 | 5.878 |
| 1120 | 5.976 |
| 1130 | 6.075 |
| 1140 | 6.175 |
| 1150 | 6.276 |
| 1160 | 6.377 |
| 1170 | 6.478 |
| 1180 | 6.580 |
| 1190 | 6.683 |
| 1200 | 6.786 |
| 1210 | 6.890 |
| 1220 | 6.995 |
| 1230 | 7.100 |
| 1240 | 7.205 |
| 1250 | 7.311 |
| °C | mV |
|---|---|
| 1260 | 7.417 |
| 1270 | 7.524 |
| 1280 | 7.632 |
| 1290 | 7.740 |
| 1300 | 7.848 |
| 1310 | 7.957 |
| 1320 | 8.066 |
| 1330 | 8.176 |
| 1340 | 8.286 |
| 1350 | 8.397 |
| 1360 | 8.508 |
| 1370 | 8.620 |
| 1380 | 8.731 |
| 1390 | 8.844 |
| 1400 | 8.956 |
| 1410 | 9.069 |
| 1420 | 9.182 |
| 1430 | 9.296 |
| 1440 | 9.410 |
| 1450 | 9.524 |
| 1460 | 9.639 |
| 1470 | 9.753 |
| 1480 | 9.868 |
| 1490 | 9.984 |
| 1500 | 10.099 |
| 1510 | 10.215 |
| 1520 | 10.331 |
| 1530 | 10.447 |
| 1540 | 10.563 |
| 1550 | 10.679 |
| 1560 | 10.796 |
| 1570 | 10.913 |
| 1580 | 11.029 |
| 1590 | 11.146 |
| 1600 | 11.263 |
| 1610 | 11.380 |
| 1620 | 11.497 |
| 1630 | 11.614 |
| 1640 | 11.731 |
| 1650 | 11.848 |
| 1660 | 11.965 |
| 1670 | 12.082 |
| °C | mV |
|---|---|
| 1680 | 12.199 |
| 1690 | 12.316 |
| 1700 | 12.433 |
| 1710 | 12.549 |
| 1720 | 12.666 |
| 1730 | 12.782 |
| 1740 | 12.898 |
| 1750 | 13.014 |
| 1760 | 13.130 |
| 1770 | 13.246 |
| 1780 | 13.361 |
| 1790 | 13.476 |
| 1800 | 13.591 |
| 1810 | 13.706 |
| 1820 | 13.820 |
What about the cold junction?
In the field the reference junction sits at the transmitter or instrument terminals, almost never at 0 °C. So the voltage measured at the terminals is not the table value: the instrument compensates the cold junction. To check a mV reading, take the terminal temperature into account.
Calculated reference values, not measurements. The thermocouple tolerance depends on its class (IEC 60584-1) and is not in the table.
Values calculated from the reference functions; they do not replace measurement or a calibration certificate.